The car air conditioning not working Diaries



Glad to listen to that it is working now therefore you aided extend the life of your respective device by replacing the contactor. I hope that your unit continues to operate very well. Steve

Hi Laura! Sorry to hear you're possessing issues with you air conditioning technique. This feels like a thermostat issue or possibly a unfastened thermostat wire difficulty. The thermostat really should send 24 volts from the “G” inexperienced thermostat wire and 24 volts through the “Y” thermostat wire once the thermostat is looking for cooling. The green wire controls the indoor air handler lover relay plus the yellow “Y” controls the out doorway condensing device contactor which turns the out of doors condensing unit ON.

The within blower motor fuse burns up the moment the ability is added. I'm able to possess the thermostat in the off posture but The instant I activate the warmth or ac the fuse burns out. Can it be the thermostat or could it's the capacitor.

Whenever a method is very low on refrigerant, the compressor will cycle on and off routinely. If your method may be very reduced, the compressor won't turn on in the slightest degree. The system has to be checked for leaks; any leak observed needs to be fixed and the system thoroughly evacuated and recharged.

I have a air-source heat pump that was set up this summer, having an aged Payne air handler/furnace. If they mounted it and analyzed the AUX Warmth, the 5amp fuse blew. They changed the fuse and tried out yet again and it gave the impression to be working (challenging to tell – they ended up running it with a 90 diploma working day).



I have a problem that has a Goodman Warmth Pump that’s only a couple several years old. Final night time we had torrential rains. As typical, I turned the thermostat right down to 73 ahead of about to bed And so the A/C would keep us interesting although sleeping. My wife woke me up a couple of several hours afterwards telling me some thing was Incorrect with it. I obtained up and it was eighty one° in your home. I checked along with the air coming out of your register was ninety eight°. I turned the device off within the thermostat and waited a couple of minutes and started it all over again.

Hello Curt! Thanks for asking this concern. Considering that the compressor runs for weeks and times after you reset the thermostat, then this could not become a compressor challenge aside from the compressor maybe overheating and heading off on thermal above-load. The following time this problem takes place I'd personally advise that you simply change the ability off towards your device and see it the compressor is very hot. If it is genuine very hot on best then there's a chance you're lower on refrigerant demand and the minimal refrigerant is not click here holding the compressor neat plenty of producing it to go off on thermal in excess of-load. I will not realize why that resetting the thermostat fixes the situation in addition to probably a relay about the thermostat or Management board in your out of doors unit is becoming worn where it works at times and in some cases it doesn't work.

Overload checks high-quality and compressor seems to as well when I utilize the ohms check, but if the unit is jogging, I only see about 66vac in the least 3 of the terminals to the LG compressor. Any Strategies? thx beforehand, Doug.

I can find the precise design, nevertheless it’s near to $two hundred, whilst other motors that seem to me like they would do the job (identical producer) are less than 50 % as costly.

I might suggest that you just exchange the whole read more device and change the evaporator coil with a matched coil. The business must use the Tremendous heat system for charging your device For those who have a cap tube or piston metering product and also the subcooling method to cost your technique For those who have a thermostatic expansion valve metering machine. The pressures and temperatures really should inform the technician When the device is functioning effectively and charged up effectively. I'm sorry which i cannot be much enable. Steve

Hi steve! i have rheem heat pump. it really is about 15 a long time previous, never ever had any troubles. whenever we turned within the ac it did not toss out extremely chilly air and we were not finding any h2o out with the drip outdoors the house. what might be the situation Thanks FOR Your time and effort!

If you do not have a warmth pump and have fuel or electric powered warmth then the out of doors device will likely not run. The out of doors device will only run while in the air conditioning manner If you don't check here Use a heat pump and have electric powered or fuel warmth. I hope you do have a good day! Steve

Hi, yesterday when we obtained residence around eight;thirty pm. ,i recognized straight away that our ac unit was not working, Now we have a three ton provider heat pump device, I could push the examination Make contact with and unit would function and blow chilly air, once i Allow go it could Stop, so these days i started off examining items eventually i pulled the insulation blanket off compressor and there is a black plastic box to the side of the compressor, tapped it and i read a loud click, then everything went to working since it should, any ideas exactly what the plastic box is, and will i change it?, Many thanks and God Bless to you personally and yours, Monte

Hi, I've a 5ton trane product XE1000 TWR060C100A3. Just lately the cap and contactor were being burnt out and changed and anything seems to be working smoothly right until thermostat reaches established temp. When this occurs out of doors unit lover stops managing but sounds like compressor keeps functioning for a few minutes.